iQ-Flatlight

    A spectrally programmable iQ-LED light source for test chart illumination

    iQ-Flatlight

    iQ-Flatlight

    Product Overview

    One of the most important aspects of image quality testing is ensuring that your reflective test chart or test scene is properly illuminated. Many labs have only standard light sources, which cannot create a wide range of lighting conditions. The iQ-Flatlight addresses this issue with iQ-LED technology.

    iQ-LED V2 technology is a light source that is capable of generating custom spectra to replicate various light sources in a test lab environment. As with our other iQ-LED products, the iQ-Flatlight uses 20 LED channels to emulate almost any light spectrum for your camera testing. Each light contains ten iQ-LED V2 elements, achieving a maximum intensity of 2000 lux per pair on the chart plane and a spectral range of 380-820 nm.

    With the introduction of iQ-LED V2, it is now possible to control the lights' functionality without a PC. You can store up to 44 distinct illuminants and one sequence on the device (controlled via microswitches on the device).

    The iQ-Flatlight uses a mini-spectrometer with a spectral range of 350–860 nm to achieve higher spectral resolution and sensitivity. The spectrometer is also able to calibrate the lights.

    It is also the perfect complement for VCX testing. All of the light sources outlined in the VCX white paper can be recreated with the iQ-LED, which allows for more efficient VCX mobile phone testing.

    The iQ-Flatlight is always sold as a pair of two and includes iQ-LED control software (which has predefined standard illuminants) and a height-adjustable rolling cart for each light. We also offer an iQ-LED API as a separate option.

    Each iQ-Flatlight is available with the standard 10 iQ-LED modules.

    Key Benefits

    iQ-LED light source

    The iQ-Flatlight uses iQ-LED technology to generate custom spectra for advanced and flexible camera testing.

    Reflective target illumination

    The iQ-Flatlights are ideal for uniformly illuminating reflective test targets/charts.

    High uniformity

    The iQ-Flatlight provides a uniformity of >90% on a large test chart (sample setup).

    VCX test setups

    The iQ-Flatlight is the ideal light source for testing mobile phone and webcam systems according the VCX standard.

    Customization options

    We can provide versions of the iQ-Flatlight with additional wavelengths, e.g., extending the visible spectrum into the infrared (on request).

    Software and APIs

    iQ-Flatlight can be controlled using the iQ-LED control software, and we also offer an iQ-LED API.

    iQ-Flatlight - Basic

    As a basic setup, you can also choose to have the iQ-Flatlights delivered without a spectrometer* and instead with a device preconfigured with illuminants. These illuminants must be individually requested (up to 40) and programmed into your device before delivery.

    This option significantly reduces the product's total cost and is an excellent choice for new or smaller test labs looking to upgrade their image quality testing.

    Please contact our sales department to get started with a basic product.

    *A spectrometer can be purchased at a later date if desired.

    Custom Options

    We are happy to discuss our customers' needs and can also provide versions of the iQ-Flatlight with additional wavelengths, e.g., extending the visible spectrum into the infrared. Please get in touch if you are interested in customization options.

    Contact our sales department for details and customization.

    Use Case

    Typical application area

    VCX Mobile Phone Testing

    The VCX-PhoneCam standard outlines test procedures and metrics for evaluating image quality in mobile phone camera systems. The VCX-Forum is a non-profit organization that provides objective camera test measurements and metrics to determine a final score for each mobile phone camera system. The purpose is to provide consumers with an objective evaluation when they are searching for a new phone. The VCX test includes metrics such as resolution, texture loss, color accuracy, visual noise, dynamic range, and distortion, among others. Each metric must be tested under defined lighting conditions, e.g., bright and low-light. Using iQ-LED technology, the iQ-Flatlight can generate each lighting condition outlined in the standard. This solution provides an all-in-one light source for testing cameras across various lighting conditions.

    Technical Specifications

    SpecificationValue
    Light source 10 x iQ-LED V2 each with 41 SMD high power LEDs separated into 20 color channels
    Spectral range 380 – 820 nm
    Uniformity> 90% (with two iQ-Flatlights in ~1.5 m distance, depending on test setup)
    Predefined standard illuminantsD50, D55, D65, D75, A, B, C, E
    Illumination stability+/- 1% when stabilized (2% after switching D illuminants in the first 5 seconds)
    Maximum / Minimum illumination valuesSingle iQ-Flatlight (400 mm distance) 25 lx up to 7800 lx | Two iQ-Flatlights (in ≈ 1.5 m distance) 10 lx up to 2000 lx depending on test setup (for standard D illuminants)
    IntensityControlled via 4000 steps per channel and 32 kHz PWM (switchable to 1000 steps with 128 kHz)
    Dimensions (W x H x D)870 x 1530 - 1830 x 710 mm (300 mm height adjustable)
    Weight65 kg

    Software Downloads

    Download the latest version of the iQ-LED Software. Click here for documentation.

    iQ-LED Control Software

    iQ-LED software V3.6.0 - Windows 64bit installer

    iQ-LED API

    Please contact our sales team for the download link.

    Documentation

    Download technical specifications and other important documents.

    iQ-Flatlight Datasheet

    Technical specifications and product details

    iQ-Flatlight User Manual

    Complete operating instructions

    iQ-LED Product Line Flyer

    A basic overview of the iQ-LED product line

    iQ-LED control software user manual

    Complete operating instructions for the iQ-LED control software